monitor
#monitor#7933

7933

Product Name Event ID 7933 Event Source MSSQLSERVER Component SQLEngine Symbolic Name DBCC2_FS_ORPHANED_ROWSET_DIRECTORY Message

Product

Name

Event ID

7933

Event Source

MSSQLSERVER

Component

SQLEngine

Symbolic

Name

DBCC2_FS_ORPHANED_ROWSET_DIRECTORY

Message Text

Table error: A Filestream directory ID F_ID exists for a partition, but the corresponding

partition does not exist in the database.

During DBCC CHECKDB, a rowset directory was found in the FILESTREAM dataspace; however,

its corresponding partition is missing in the database.

Run hardware diagnostics and correct any problems. Also examine the Microsoft Windows

system and application logs and the SQL Server error log to see whether the error occurred as

the result of hardware failure. Fix any hardware-related problems that are contained in the logs.

If you have persistent data corruption problems, try to swap out different hardware

components to isolate the problem. Check to make sure that the system does not have write-

caching enabled on the disk controller. If you suspect write-caching to be the problem, contact

your hardware vendor.

Expand table