monitor
#monitor#7905

7905

Product Name Event ID 7905 Event Source MSSQLSERVER Component SQLEngine Symbolic Name DBCC2_FS_INVALID_ROWSET_DIRECTORY Message Te

Product Name

Event ID

7905

Event Source

MSSQLSERVER

Component

SQLEngine

Symbolic Name

DBCC2_FS_INVALID_ROWSET_DIRECTORY

Message Text

Database error: The directory ‘DIRECTORY’ is not a valid Filestream directory.

The name of a rowset directory is the partition ID of the partition, except for the special rowset

directory names such as ‘ghost’. If a rowset directory name cannot be converted to a partition

ID, the directory is not a valid rowset directory.

Run hardware diagnostics and correct any problems. Also examine the Microsoft Windows

system and application logs and the SQL Server error log to see whether the error occurred as

the result of hardware failure. Fix any hardware-related problems that are contained in the logs.

If you have persistent data corruption problems, try to swap out different hardware

components to isolate the problem. Check to make sure that the system does not have write-

caching enabled on the disk controller. If you suspect write-caching to be the problem, contact

your hardware vendor.

Expand table