5233
Product Name Event ID 5233 Event Source MSSQLSERVER Component SQLEngine Symbolic Name DBCC4_INCORRECT_VALUE_IN_PAGE_HEADER_NO_META
Product Name
Event ID
5233
Event Source
MSSQLSERVER
Component
SQLEngine
Symbolic
Name
DBCC4_INCORRECT_VALUE_IN_PAGE_HEADER_NO_METADATA
Message Text
Table error: alloc unit ID A_ID, page P_ID. The test (TEST) failed. The values are VAL1 and
VAL2.
Page
P_ID
has failed auditing due to a corruption in its page header. The string in TEST gives
the actual test that failed.
Run hardware diagnostics and correct any problems. Also examine the Microsoft Windows
system and application logs and the SQL Server error log to see whether the error occurred as
the result of hardware failure. Fix any hardware-related problems that are contained in the logs.
If you have persistent data corruption problems, try to swap out different hardware
components to isolate the problem. Check to make sure that the system does not have write-
caching enabled on the disk controller. If you suspect write-caching to be the problem, contact
your hardware vendor.
Finally, you might find it useful to switch to a new hardware system. This switch may include
reformatting the disk drives and reinstalling the operating system.