monitor
#monitor#5233

5233

Product Name Event ID 5233 Event Source MSSQLSERVER Component SQLEngine Symbolic Name DBCC4_INCORRECT_VALUE_IN_PAGE_HEADER_NO_META

Product Name

Event ID

5233

Event Source

MSSQLSERVER

Component

SQLEngine

Symbolic

Name

DBCC4_INCORRECT_VALUE_IN_PAGE_HEADER_NO_METADATA

Message Text

Table error: alloc unit ID A_ID, page P_ID. The test (TEST) failed. The values are VAL1 and

VAL2.

Page

P_ID

has failed auditing due to a corruption in its page header. The string in TEST gives

the actual test that failed.

Run hardware diagnostics and correct any problems. Also examine the Microsoft Windows

system and application logs and the SQL Server error log to see whether the error occurred as

the result of hardware failure. Fix any hardware-related problems that are contained in the logs.

If you have persistent data corruption problems, try to swap out different hardware

components to isolate the problem. Check to make sure that the system does not have write-

caching enabled on the disk controller. If you suspect write-caching to be the problem, contact

your hardware vendor.

Finally, you might find it useful to switch to a new hardware system. This switch may include

reformatting the disk drives and reinstalling the operating system.

Expand table