monitor
#monitor#5228

5228

Product Name Event ID 5228 Event Source MSSQLSERVER Component SQLEngine Symbolic Name DBCC4_ANTIMATTER_COLUMN_DETECTED Message

Product

Name

Event ID

5228

Event

Source

MSSQLSERVER

Component

SQLEngine

Symbolic

Name

DBCC4_ANTIMATTER_COLUMN_DETECTED

Message

Text

Table error: Object ID O_ID, index ID I_ID, partition ID PN_ID, alloc unit ID A_ID (type TYPE),

page PG_ID, row R_ID. DBCC detected incomplete cleanup from an online index build

operation. (Antimatter column value is VALUE.)

An unfinished online index build was detected for object

O_ID

, index

I_ID

, and partition

PN_ID.

This is manifested by the presence of an antimatter column on the row

R_ID. An antimatter

column is used when reconciling records from multiple sources during an online index build.

The error message also indicates the value of the antimatter column.

Run hardware diagnostics and correct any problems. Also examine the Microsoft Windows

system and application logs and the SQL Server error log to see whether the error occurred as

the result of hardware failure. Fix any hardware-related problems that are contained in the logs.

Expand table