Product Name Event ID 2575 Event Source MSSQLSERVER Component SQLEngine Symbolic Name DBCC_IAM_PAGE_WAS_NOT_SEEN Message Text

Product

Name

Event ID

2575

Event Source

MSSQLSERVER

Component

SQLEngine

Symbolic

Name

DBCC_IAM_PAGE_WAS_NOT_SEEN

Message

Text

IAM page P_ID1 is pointed to by the next pointer of IAM page P_ID2 in object ID O_ID,

index ID I_ID, partition ID PN_ID, alloc unit ID A_ID (type TYPE) but was not detected in the

scan.

An Index Allocation Map (IAM) page was found for the specified index; however, the IAM page

for its next-page pointer was not found.

Run hardware diagnostics and correct any problems. Also examine the Microsoft Windows

system and application logs and the SQL Server error log to see whether the error occurred as

the result of hardware failure. Fix any hardware-related problems that are contained in the logs.

If you have persistent data corruption problems, try to swap out different hardware

components to isolate the problem. Check to make sure that the system does not have write-

Expand table