2575
Product Name Event ID 2575 Event Source MSSQLSERVER Component SQLEngine Symbolic Name DBCC_IAM_PAGE_WAS_NOT_SEEN Message Text
Product
Name
Event ID
2575
Event Source
MSSQLSERVER
Component
SQLEngine
Symbolic
Name
DBCC_IAM_PAGE_WAS_NOT_SEEN
Message
Text
IAM page P_ID1 is pointed to by the next pointer of IAM page P_ID2 in object ID O_ID,
index ID I_ID, partition ID PN_ID, alloc unit ID A_ID (type TYPE) but was not detected in the
scan.
An Index Allocation Map (IAM) page was found for the specified index; however, the IAM page
for its next-page pointer was not found.
Run hardware diagnostics and correct any problems. Also examine the Microsoft Windows
system and application logs and the SQL Server error log to see whether the error occurred as
the result of hardware failure. Fix any hardware-related problems that are contained in the logs.
If you have persistent data corruption problems, try to swap out different hardware
components to isolate the problem. Check to make sure that the system does not have write-
ノ