17207
Product Name Event ID 17207 Event Source MSSQLSERVER Component SQLEngine Symbolic Name DBLKIO_OS2DISKERROR Message Text %ls: Op
Product
Name
Event ID
17207
Event Source
MSSQLSERVER
Component
SQLEngine
Symbolic
Name
DBLKIO_OS2DISKERROR
Message Text
%ls: Operating system error %ls occurred while creating or opening file ‘%ls’. Diagnose
and correct the operating system error, and retry the operation.
was unable to open the specified file because of the specified OS error.
You may see error 17207 in the Windows Application Event or the SQL Server Error log when
cannot open a database and/or transaction log files. Here is an example of what the
error may look like.
You may see these errors during the SQL Server instance startup process or any database
operation that attempts to start the database (for example, ALTER DATABASE). In some
ノ
Expand table
Error: 17207, Severity: 16, State: 1.
FileMgr::StartSecondaryDataFiles: Operating system error 2(The system cannot find the file specified.) occurred while creating or opening file
'F:\MSSQL\DATA\MyDB_FG1_1.ndf'. Diagnose and correct the operating system error,
and retry the operation.